The hard chamber is composed of stainless steel and tempered glass.
The Chamber is made of 316L stainless steel as a whole, and all inner comers are rounded comers for easy cleaning and sterilization.
Completely unidirectional airflow mode provides excellent aseptic operating area.
The airflow mode is vertical, unidirectional airflow which can quickly eliminate biodegradable substances during ventilation.
Material door is designed for inflatable sealed and possess the function of pneumatic locking and working state interlocking.
Integrated and stand-alone hydrogen peroxide sterilization can effectively reduce the bio-active substances pollution up to 106.
Adopts Siemens Programmable logic controller (PLC) and integrated the signal acquisition, real-time data display,high and low voltage alarm,data storage and printing function.
Hour leakage rate <0.5%, absolutely guarantee the reliability of product quality and the safety of the operator ,and the test bases on 15014644-7.2004 and GB/T 25915.72010
Provide a detected system and configuring according to the customers different process characteristics and requirements and suit for different batches and process needs.
The air chamber can be continuously decontaminated on the surface of the product to avoid contamination caused by material transfer and meet the needs of rapid and multi-batch of experiment.
Positive and negative pressure is adjustable and can be used for sterility testing and positive bacteria detection, sterility sampling(weighing and packaging), etc.
Model | Size of machine | Size of Operation | Pre-chamber | Description |
---|---|---|---|---|
SP-L1500 | 1500*1100*2300 | 1500*700*800 | NO | Single-sided hard cabin laminar flow isolator 3 gloves |
Sp-L1500 | A2100*1100*2300 | 1500*700*800 | 500*600*500 | Single-sided hard cabin laminar flow isolator 3 gloves |
Sp-L1800 | 1800*1100*2300 | 1800*700*800 | NO | Single-sided hard cabin laminar flow isolator 4 gloves |
SP-L1800A | 2400*1100*2300 | 1800*700*800 | 500*600*500 | Single-sided hard cabin laminar flow isolator 4 gloves |
SP-DL1800A | A2450*1100*2300 | 1800*1000*800 | 500*600*500 | Single-sided hard cabin laminar flow isolator 4+4 gloves |
Power:2500W
Noise::c::; 60dB(A)
Airspeed :0.36to0.54m/s
High Efficiency Particulate Air Filter:Grade H14 with 99.995% of filtering efficiency
PSterilizing Ratio;106 for fat thermoplastic spore
SizeofTouchScreen:10inch
Pressure control :-80 to 80Pa
Pressure Resolution:0.1Pa
Humidity Resolution:0.1%
Temperature Resolution:0.1C
Airflow model:Vertical unidirectional flow
Purification Grade of Chamber Interior: Grade A at dynamic status